MD100 Chlorine Dioxide Kit

Posted by craig.f@dtkwater.com
MD100-ClO2-455x455

Photometer dedicated to Chlorine Dioxide testing.

    • Contains MD 100 Photometer available complete with reagents & accessories
    • Accurately measures Chlorine Dioxide between 0.02 to 11 mg/l

Description

Additional components such as pH and conductivity meters and drop test chemistries may also be added to the kit, providing a bespoke and complete analysis program.

For more details on the MD100, including technical specifications please look at the Lovibond MD100 page

MD100 Chlorine Dioxide Photometer Kit

Contents Range Displayed As Code
2011 Medium Case with Foams
Instructions
Tablet Crusher
Cell Cleaning Brush
3 x Cells
Batteries
Screw Driver (for battery compartment access)
Chlorine Dioxide
0.02 to 11
mg/l CO2
DPD No 1 Tablet (50 pk) SDT106-50

MD100 Chlorine Kit

Posted by craig.f@dtkwater.com
MD100_Boiler_Cooling_cut_400x400

Photometer dedicated to Chlorine testing.

    • Contains MD 100 Photometer available complete with reagents & accessories
    • Accurately measures Chlorine between 0.01 to 6 mg/l
    • Photometer can measure up to 10 mg/l (reagents not included)

Description

Additional components such as pH and conductivity meters and drop test chemistries may also be added to the kit, providing a bespoke and complete analysis program.

For more details on the MD100, including technical specifications please look at the Lovibond MD100 page

MD100 Chlorine Photometer Kit

Contents Range Displayed As Code
2011 Medium Case with Foams
Instructions
Tablet Crusher
Cell Cleaning Brush
3 x Cells
Batteries
Screw Driver (for battery compartment access)
Chlorine
0.01 to 6
mg/l Cl2
DPD No 1 Tablet (50 pk) SDT106-50
DPD No 3 Tablet (50 pk) SDT107-50

MD640 PHOTOMETER

Posted by craig.f@dtkwater.com

Photometer and Fluorometer

MD640 800x800

      • PTSA within a high accuracy field photometer
      • Built-in PTSA measurement without adapter.
      • Over 120 methods.
      • PTSA measurement (florescence).
      • Data storage and transfer.
      • Bluetooth® connectivity

EXTENSIVE COVERAGE

The MD 640 has all the features of the MD 610, with added florescence capability for the determination of PTSA in water systems.

PTSA (1,3,6,8 pyrenetetrasulfonic acid, sodium salt) is a fluorescent material that is being increasingly added to specialty water treatment products to enable real time product dose analysis.

PTSA is detectable at ppb levels, is non-toxic and chemically stable, making it an ideal additive to trace throughout complex water systems.

The MD 640 has a built-in UV excitation LED that enables accurate detection and quantification of PTSA from 0 to 1000 ppb. No additional adapters or reagents required, just insert the sample and read the result.

Accurately measuring product dose levels help the water treatment specialist to control water chemistry; prevent corrosion, scale and biological fouling; increase system efficiency and ultimately save energy and costs.

The MD 640 is pre-programmed with over 120 analytical methods to enable quantification of naturally occurring dissolved metals and non-metals such as copper, iron, calcium, magnesium and carbonates, plus a range of water treatment additives such as DEHA, Molybdenum phosphate, poylacrylates, PTSA, organo-phosphate (phosphonates) and more empowering the field engineer to effectively manage many different water systems and treatments with one compact, waterproof and rugged handheld device.

Chemical Structure of PTSA

PTSA Diagram

The Bluetooth® mark, figure mark and combination mark are trademarks owned by the Bluetooth SIG and any use by the Tintometer® Group is under license.

MD100 COOLING WATER

Posted by admin
MD100_Cooling_1000x1000

Photometer Dedicated to Cooling / Closed Systems Water

    • One instrument to carry out all the tests associated with cooling water / closed water systems.
    • Ideal for routine, on-site system monitoring.
    • Photometric measurement for accurate, repeatable results.
    • Easy-to-use, push button technology with step to step guides.
    • Select range of required reagents to complete your kit.
    • Combine with pH, conductivity and drop test chemistries to provide a complete analysis program.

Description

The engineer can select and incorporate the Lovibond® / DTK Water reagents required for the monitoring of specific water treatment inhibitors. Additional components such as pH and conductivity meters and drop test chemistries may also be added to the kit, providing a bespoke and complete analysis program.

For more details on the MD100, including technical specifications please look at the Lovibond MD100 page

MD100 Cooling / Closed Water Systems Photometer

Parameters Range Displayed As Code
Aluminium
0.01 to 0.25
mg/l Al
VARIO Aluminium ECR/F20 Powder Pack (100 pk) 53500 (set)
VARIO Aluminium Hexamine/F20 Powder Pack (100 pk)
VARIO Aluminium ECR Masking Reagent (25 ml)
Bromine 0.05 to 13 mg/l Br2
DPD No 1 Tablets (50 pk) SDT106-50
DPD No 3 Tablets (50 pk) SDT107-50
DPD Glycine Tablets (50 pk) SDT146-50
Chlorine
0.01 to 6
mg/l Cl2
DPD No 1 Tablet (50 pk) SDT106-50
DPD No 3 Tablet (50 pk) SDT107-50
Chlorine HR
5 to 200
mg/l Cl2
Acidifying GP Tablets (50 pk) SDT045
Chlorine HR (KI) Tablet (50 pk) SDT221-50
Chlorine Dioxide
0.02 to 11
mg/l CO2
DPD No 1 Tablets (50 pk) SDT106-50
DPD Glycine Tablets (50 pk) SDT146-50
Copper 0.3 to 5 mg/l Cu
Copper No 1 Tablets (50 pk) SDT240-50
Copper No 2 Tablets (50 pk) SDT239-50
Iron LR 0.03 to 2 mg/l Fe
FE5 – Iron LR Reagent (65 ml) SDT110
Iron, total (Fe in Mo) in presence of Molybdate 0.03 to 2 mg/l Fe
VARIO Iron in Mo Rgt 1 Powder Pack (100 pk) 536010 (set)
VARIO Iron in Mo Rgt 2 Powder Pack (100 pk)
Molybdenum LR
0.03 to 3
mg/l Mo
VARIO Molybdenum 1 LR F20 Powder Pack (50 pk) 535450 (set)
VARIO Molybdenum 2 LR Liquid (50 ml)
Molybdenum HR
0.6 to 60
mg/l Mo
Molybdate HR Reagent (65 ml) SDT127
Ozone 0.02 to 2 mg/l O2
DPD No 1 Tablets (50 pk) SDT106-50
DPD No 3 Tablets (50 pk) SDT107-50
DPD Glycine Tablets (50 pk) SDT146-50
Polyacrylate 1 to 30 mg/l Polyacrylate
A1 – Buffer (65 ml) SDT082
A2 – Precipitant (65 ml) SDT083
Sulphate 5 to 100 mg/l SO4
VARIO Sulphate 4 / F10 Powder Pack (100 pk) 532160
Triazole (UV lamp required) 1 to 16 mg/l Benzotriazole
VARIO Triazole Rgt F25 Powder Pack (100 pk) 532200
Zinc 0.1 to 2.5 mg/l Zn
Zinc Reagent 1 (65 ml) SDT167
Zinc Reagent 2 (20 g) SDT168

MD100 BOILER WATER

Posted by admin
MD100_Boiler_Cooling_cut_400x400

Photometer Dedicated to Boiler Water

    • One instrument to carry out all the tests associated with boiler water systems.
    • Ideal for routine, on-site system monitoring.
    • Photometric measurement for accurate, repeatable results.
    • Easy-to-use, push button technology with step to step guides.
    • Select range of required reagents to complete your kit.
    • Combine with pH, conductivity and drop test chemistries to provide a complete analysis program.

Description

The engineer can select and incorporate the Lovibond® / DTK Water reagents required for the monitoring of specific water treatment inhibitors. Additional components such as pH and conductivity meters and drop test chemistries may also be added to the kit, providing a bespoke and complete analysis program.

For more details on the MD100, including technical specifications please look at the Lovibond MD100 page

MD100 Boiler Water Photometer

Contents Range Displayed As Code
Aluminium
0.01 to 0.25
mg/l Al
VARIO Aluminium ECR/F20 Powder Pack (100 pk) 53500 (set)
VARIO Aluminium Hexamine/F20 Powder Pack (100 pk)
VARIO Aluminium ECR Masking Reagent (25 ml)
Chloride
0.5 to 20
mg/l Cl
Chloride Reagent A (65 ml) SDT859
Chloride Reagent B (65 ml) SDT860
Copper 0.3 to 5 mg/l Cu
Copper No 1 Tablets (50 pk) SDT240-50
Copper No 2 Tablets (50 pk) SDT239-50
DEHA 20 to 500 µg/l
VARIO Oxyscav 1 Rgt Powder Pack (200 pk) 536000 (set)
VARIO DEHA 2 Rgt (100 ml)
Hydrazine 50 to 500 µg/l N2H4
Hydrazine Test Powder (40 g) SDT551
Iron LR 0.03 to 2 mg/l Fe
FE5 – Iron LR Reagent (65 ml) SDT110
Oxygen, dissolved with Vacu-Vials® 10 to 800 µg/l O2
Vacu-vial® Liquid (30 ml) K-7553
Phosphate 5 to 80 mg/l PO4
PB1 – Phosphate HR (65 ml) SDT111
PB2 – Phosphate HR (65 ml) SDT112
Polyacrylate 1 to 30 mg/l
A1 – Buffer (65 ml) SDT082
A2 – Precipitant (65 ml) SDT083
Silica HR 1 to 90 mg/l SiO2
VARIO Silica HR Molybdate F10 Powder Pack (100 pk) 535700 (set)
VARIO Silica HR Acid Rgt F10 Powder Pack (100 pk)
VARIO Silica HR Citric Acid F10 Powder Pack (100 pk)

AQUALX APP

Posted by craig.f@dtkwater.com

 

appstore_logo_1024_1024

An overview of the app functions

  • Creation of any number of users, customers, or measuring locations.
  • Integrated data management.
  • Sorting and representation of measurements according to sampling locations, customers, parameters, etc.
  • Linking of customers with measuring locations.
  • Individually adaptable minimum and maximum values of a measuring method
  • Readout of measurements at precise times in figures or graphics
  • Graphic evaluations over various time periods
  • Sending of results via email

New data processing possibilities for Lovibond® photometer systems

The AquaLX® app is the ideal supplement to Lovibond photometers. With the Bluetooth® interface, measuring results for quick evaluation and processing can be transmitted to smart phones or tablets, so all data can be evaluated and allocated directly on site. The app displays all measurements in a clear graph with minimum and maximum thresholds and supports data export as an Excel®-compatible CSV file.

apple01google

System Requirements:

  • Lovibond® MD 610 or PM 630 photometer.
  • Bluetooth®-capable smart phone or tablet.
  • Android™ version 4.3 or later
  • iOS® 7 or later

Information for Bluetooth®

Bluetooth ® is a wireless technology subject to regional approval. The use of Bluetooth® is currently only permitted in limited regions.

MD100 PHOTOMETER

Posted by craig.f@dtkwater.com
The_Tintometer_Ltd_MD100_waterproof_compact_portable_photometer_3

Key Features

    • Waterproof (as defined in IP 68, 1 hour at 0.1m).
    • Automatic Switch-Off.
    • Real-Time-Clock and Date.
    • Calibration Mode.
    • Backlit Display.
    • Storage Function.
    • Suitable for use as a testing instrument.

Description

The MD100 uses high quality interference filters with long-life LEDs as a light source without any moving parts in a transparency sample chamber. The units supply accurate, reproducible results very quickly. Other major advantages include ease of operation, ergonomic design, compact dimensions
and safe handling.
The calibration and software-based adjustment options mean that the MD100 is also suitable for use as a testing instrument.

MD100_Boiler_Cooling_cut_400x400

Applications

The MD100 Photometer is used in a wide range of water testing applications including Industrial water treatment, Boiler, cooling and closed system analysis, Process water, Pre-treatment plant, Effluent water, Science & research, Laboratories and Mobile applications.

Available Methods

There are mutliple MD100’s available with a wide range of parameters available. For information on the MD100 Cooling Water please see here. For information on the MD100 Boiler Water please see here

IRIM Infra-Red Data Transmission Module

The IRIM (Infra-red data transmission module) uses modern infra-red technology to transmit data from the MD100 to one of 3 optional interfaces. This allows the MD100 to be connected to a computer or printer. For more information on the IRIM click here.

For enquiries please email:
info@dtkwater.com

N.I.S.T Tracability

The instrument has a factory calibration, which is related to international standards which are not N.I.S.T traceable. The instrument may be calibrated by the user in a “user calibration mode” with N.I.S.T traceable standards. (N.I.S.T – National Institute of Standards and Technology)

Further Information

For further information on the MD100 photometer including available parameters, you may wish to look at our sales literature which can be downloaded here.

Technical Specification

Feature
Specification
Display:
Backlit LCD (on keypress)
Interface:
Infra-red interface for test data transfer*
Optics:
LED’s, interference filters (IF) and photo sensor in transparent sample chamber.
Wavelength range:
430 nm IF Δλ = 5 nm
530 nm IF Δλ = 5 nm
560 nm IF Δλ = 5 nm
580 nm IF Δλ = 5 nm
610 nm IF Δλ = 6 nm
660 nm IF Δλ = 5 nm
IF = interference filter
Wavelength Accuracy:
± 1 nm
Photometric Accuracy*:
3% FS (T = 20°C – 25°C)
Photometric Resolution:
0.01 A
Operation:
Acid and solvent resistant, touch-sensitive keypad with audible feedback via integrated beeper
Power supply:
4 AAA batteries
Operation time:
approx 17 hours continuous or 5000 tests
Auto-off:
Approx 20 minutes after last key press with audible signal
Dimensions:
Approx 155 x 75 x 35 mm (unit)
Weight (unit):
Approx 260 g
Ambient conditions:
5 – 40°C at max.
30 – 90% rel. humidity
(non-condensing)
Languages:
English, German, French, Spanish, Italian, Portuguese, Polish, Indonesian; additional languages available via internet download
Memory:
Up to 16 data sets

*IRIM infra-red interface module required for data transmission
**Tested with standard solutions

DATA ACQUISITION SOFTWARE

Posted by admin
DataCD_250x250

The Data Acquisition Software allows easy transmission of stored data to a PC. For transmission of data from the MD610 the IRiM (infra red interface module) is required.

DATA ACQUISITION SOFTWARE

The software will provide an easy and rapid transfer of data to the PC. The software allows for the data to be exported as an Excel file or as a .txt file for easy integration into your business.

Measurement data can quickly be printed using a specified USB or alternatively a printer with a serial plug-in connected to the IRIM.

Applicable for the following operating systems: Windows XP, Windows Vista and Windows 7.

The Data Acquisition Software includes

  • IRiM-Driver
  • Software Manual
  • IRiM Manual

VERIFICATION STANDARD KIT

Posted by admin
reference_standard_250x250

KEY FEATURES

    • Zero solution in sealed photometer vial.
    • 6 x Verification Standard Solution in sealed photometer vial.
    • Light Shield Cap.
    • Certificate of conformity.
    • Instruction sheet.

The verification standard kit for the MD610 is designed to ensure the accuracy of the photometer and reliability of the results.

The kit contains a set of standard solution specific to each wavelength used by the photometer. This allows the user to verify the performance of the photometer over the full measurement range. Once measured, results are then compared against tolerances provided on the certificate of conformity.

The kit has a shelf life of 2 years from the date of preparation.

ORDER CODES

CODE
DESCRIPTION
21 56 40
Verification Standard Kit
Includes:
Zero solution in sealed photometer vial
6 x Verification Standard Solution in sealed photometer vial
Light shield cap
Certificate of conformity
Operating Instructions

INFRA-RED DATA TRANSMISSION MODULE

Posted by admin
IRIM_250x250

IRIM

The IRIM (Infra-red interface module) uses modern infra-red technology to transmit measurement data from the MD610 to one of three optional interfaces. These interfaces can be used to connect to PC, a USB printer or a serial printer.

The interface which is selected is signalled by an LED indicator. The user can easily switch between interfaces using the select button.

DATA ACQUISITION SOFTWARE

The unit is supplied with our data logging software which will provide an easy and rapid transfer of data to the PC. The software allows for the data to be exported as an Excel file or as a .txt file for easy integration into your business.

Measurement data can quickly be printed using a specified USB or alternatively a printer with a serial plug-in connected to the IRIM.

Applicable for the following operating systems: Windows XP, Windows Vista and Windows 7.

The IRIM is delivered ready to use, with the following accessories: USB Cable, 4 Batteries, Screwdriver, CD-ROM, Operating instructions and Guarantee certificate.

ORDER CODES

CODE
DESCRIPTION
21 40 50
IRiM Module
Includes:
USB Cable
Batteries
Screwdriver
CD-Rom
Operating Instructions
Guarantee Certificate

 

DTK Water
14 Morris Close,
Park Farm Ind Est,
Wellingborough,
NN8 6XF, UK
T: +44 (0)1604 686995
F: +44 (0)1604 686997
E: info@dtkwater.com

DTK Water is a Lovibond® company
Privacy Policy