UNIVERSAL RAPID LEGIONELLA TEST KIT
KEY FEATURES
|
|
UNIVERSAL RAPID LEGIONELLA TEST KIT The Universal Rapid Legionella Test kit is a breakthrough in technology from Hyrdosense for the rapid detection of legionella bacteria in industrial water. Test results can be obtained in minutes instead of days. The industrial legionella kits provides the user:
The test kit contains all the items required to perform 5 tests – including filters, recovery buffer, collection vessel and sample point. LEGIONELLA CONTROL This Legionella field test kit uses immunochromatographic assay, to detect the presence of cell surface antigens from Legionella bacteria in a sample. The presence of antigen causes the ‘Test Line’ to turn red in colour. A ‘Control Line’ is included which should always turn red if the test has been performed correctly. These tests are optimised for use with industrial water systems, cooling towers and whirlpool spas. The filtration step needs no pumping, just connect the sample point to the water system and use the system pressure to drive the filtration. The test follows a simple procedure and the results easily obtained within 30 to 35 minutes. Once the result is obtained the treatment engineer can asses the water condition and complete any treatment necessary to ensure there is no risk of out breaks and subsequent litigation. |
TEST KIT & INSTRUMENTS
|
REPLACEMENTS
|
|||||||||||||||||||||||||||||||||||||||
PRODUCT DETAILS |
||||||||||||||||||||||||||||||||||||||||
Bacteria detected | Legionella pneumophila serogroup 1 | |||||||||||||||||||||||||||||||||||||||
Detection method | Lateral flow immunochromatographic assay | |||||||||||||||||||||||||||||||||||||||
Lower limit of detection | Down to 100 CFU/L (0.1 CFU/mL) | |||||||||||||||||||||||||||||||||||||||
Specificity | Tested against a wide range of waterborne bacteria, including Acinetobacter calcoaceticus, Aeromonas hydrophila subsp. hydrophila, Bacillus subtilis, Burkholderia cepacia, Citrobacter freudii, Citrobacter koseri, Escherichia coli, Enterobacter cloacae, Klebsiella oxytoca, Pseudomonas aeruginosa, Pseudomonas fluorescens, Pseudomonas putida, Pseudomonas stutzeri, Ralstonia pickettii, Raoultella terrigena, Streptococcus pyrogenes, Yersinia ruckeri. No cross reactions observed at concentrations > 109 CFU/L.Staphylococcus aureus has been observed to cross react with the test at concentrations > 108 CFU/L.Legionella pneumophila serogroups 4 & 7 cross react with the test at concentrations >109 CFU/sample. The test does not react with any other L. pneumophila serogroups or L. species tested. |
|||||||||||||||||||||||||||||||||||||||
Test volume | 100 μL | |||||||||||||||||||||||||||||||||||||||
Suggested sample volume | 250 mL | |||||||||||||||||||||||||||||||||||||||
Sample parameters | Sample should filter in less than 10 minutes. | |||||||||||||||||||||||||||||||||||||||
Biocides | The product has been tested with a range of common biocides and iodispersants used in Legionella control, at their normal maximum perating concentration. Active ingredients tested include: lutaraldehyde, didecyl-dimethyl-ammonium chloride, isolthazoles, dibromonitrilopropionamide, ionic and non-ionic surfactants. The test gives a false positive if used with polymeric biguanide or THPS. |
|||||||||||||||||||||||||||||||||||||||
Operator time | 5 – 10 minutes |